6
© 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
SETTING / ADJUSTMENT
6 - 71
6.13 Adjustment of the Inner Finisher
Notes:
Before performing each adjustment, make sure that all covers (incl. those of the finisher and
equipment) are closed. Otherwise, no power is supplied to the Finisher and the adjustment may
not be performed properly.
6.13.1 Alignment position adjustment
[A] Alignment position adjustment (front)
This adjustment is performed in the Adjustment Mode (FS-05-4822-0) of the equipment.
[B] Alignment position adjustment (rear)
This adjustment is performed in the Adjustment Mode (FS-05-4822-1) of the equipment.
6.13.2 Stapling position adjustment
[A] Stapling position adjustment (rear 1-point)
This adjustment is performed in the Adjustment Mode (FS-05-4823-0) of the equipment.
[B] Stapling position adjustment (rear 1-point / “R” series size)
This adjustment is performed in the Adjustment Mode (FS-05-4823-1) of the equipment.
Adjustment scale 0.2mm
Adjustable range -3.0 mm to 3.0 mm
Adjustment direction Increasing the value The alignment plate moves to the center.
Decreasing the value The alignment plate moves to the edge of paper.
Adjustment scale 0.2mm
Adjustable range -3.0 mm to 3.0 mm
Adjustment direction Increasing the value The alignment plate moves to the center.
Decreasing the value The alignment plate moves to the edge of paper.
Adjustment scale 0.2mm
Adjustable range -5.0 mm to 5.0 mm
Adjustment direction Increasing the value The distance between the stapling position and the
edge of the paper becomes longer
Decreasing the value The distance between the stapling position and the
edge of the paper becomes shorter.
Adjustment scale 0.2mm
Adjustable range -1.0 mm to 5.0 mm
Adjustment direction Increasing the value The distance between the stapling position and the
edge of the paper becomes longer
Decreasing the value The distance between the stapling position and the
edge of the paper becomes shorter.