e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A © 2015 TOSHIBA TEC CORPORATION All rights reserved
DISASSEMBLY AND REPLACEMENT
4 - 124
4.10.5 Paper entrance guide
4.10.6 Separation finger
(1) Remove the front side cover.
P. 4-123 "4.10.2 Front side cover"
(2) Remove the rear side cover.
P. 4-123 "4.10.3 Rear side cover"
(3) Remove 2 screws, and take off the paper
entrance guide [1].
Fig. 4-334
(4) Remove 1 screw and take off the brush [2].
Fig. 4-335
(1) Remove the front side cover.
P. 4-123 "4.10.2 Front side cover"
(2) Remove the rear side cover.
P. 4-123 "4.10.3 Rear side cover"
(3) Remove 2 screws and take off the pressure
roller cover [1].
Fig. 4-336