DISASSEMBLY AND REPLACEMENT
4 - 126
4.10.7 Exit sensor (S5)
(1) Remove the fuser unit.
P. 4-121 "4.10.1 Fuser unit"
(2) Tilt the pressure lever [1].
(3) Remove 2 screws and open the pressure
roller cover [2].
Fig. 4-340
(4) Release 1 latch and take off the sensor cover
[3].
Fig. 4-341
(5) Remove the actuator [4] and spring [5].
Fig. 4-342