SETTING / ADJUSTMENT
6 - 86
[ 2 ] Resetting procedure
The setting values which are set in P. 6-80 "[ 1 ] Adjusting procedure"can be reset with the following
steps.
(1) Turn OFF the power of the equipment.
(2) Remove 1 screw and take off the board access cover.
(3) Set the SW1 on the Finisher control board as shown in the figures below.
Fig.6-89
(4) Turn ON the power of the equipment while pressing the [FUNCTION CLEAR] button and
[START] button simultaneously.
(5) Press [Button1] 11 times, press [Button2] once, press [Button1] 11 times, and then press
[Button2] once.
(6) Press [Button1] and [Button2] simultaneously.
(7) Turn OFF the power of the equipment.
(8) Turn OFF all bits of SW1 on the Finisher control board as shown below.
Fig.6-90
(9) Install the board access cover with 1 screw.