8 - 111
[CC10] Microswitch abnormality
[Procedure 3]
Is the paper pushing plate top position sensor (PI15S) connected to the saddle stitcher
controller PC board?
NO Connect it to the board.
YES
Is the wiring between the sensor and the saddle stitcher correct?
YES Correct the wiring.
NO
Is 5V DC being supplied from J9-13 on the saddle stitcher controller PC board?
NO Replace the saddle stitcher controller PC board.
YES
Is J9-14 on the saddle stitcher controller PC board properly connected to the ground?
NO Replace the saddle stitcher controller PC board.
YES
END
[Procedure 1]
Is the switch actuator for the inlet door working properly?
NO Fix the mechanism.
YES
Is the inlet cover switch (MS1S) working normally?
NO Replace the switch.
YES
Measure the voltage of J10-8 on the saddle stitcher controller PC board when the inlet door
is open. Is it 5V?
NO The inlet cover sensor (PI9S) is broken. Replace it.
YES
Measure the voltage between J1-1 (+) and J1-2 (-) on the saddle stitcher controller PC
board. Is it 24 V?
NO Replace the saddle stitcher controller PC board.
YES
Check the wiring between J19 on the finisher controller PC board and J1 on the saddle
stitcher controller PC board. If there is no problem, replace the saddle stitcher controller PC
board.