ERROR CODE AND TROUBLESHOOTING
8 - 128
[F106_2] ADI-HDD error: ADI encryption key download operation error
[F106_3] ADI-HDD error: ADI authentication Admin Password generation error
HDD • Connector check
• Harness check
• Start the equipment in the 5C mode: [5] + [C] + [POWER]
Check the file system and recover it if necessary.
If the recovery fails, replace the HDD.
If the equipment does not start in the 5C mode, also replace the HDD.
• Check that either the ADI-HDD or SATA-HDD (normal type) is mounted.
1. Start the equipment in the 4C mode: [4] + [C] + [POWER]
2. Check the type of the HDD shown on the top left of the control panel
display "Current HDD type".
Normal status: ADI-HDD or SATA-HDD
Abnormal status: Unknown HDD
If "Unknown HDD" is displayed, reinstall the system software.
Classification Error item
Other service call ADI-HDD error: Downloading of or consistency check for ADI-HDD
encryption key fails.
Check item Measures
Setting
Checking of ADI-HDD encryption key status
1. Start the equipment in the 3C mode: [3] + [C] + [POWER]
2. The authentication menu is displayed. Press [OK]. (Not required in the
default setting)
3. Select "5. Key Backup Restore" and then press the [START] button.
4. Check the status of the ADI-HDD encryption key on the Key Backup
Restore Mode menu.
5. After the operation is completed, shut down the equipment by pressing
the [POWER] button.
• In case both the SRAM ADIKey and FROM ADIKey status are OK
Reinstall the system ROM data (OS Data).
• In case either the SRAM ADIKey or FROM ADIKey status is other than
OK
Restore the ADI-HDD encryption key.
• In case both the SRAM ADIKey and FROM ADIKey status are other
than OK
Reinstall the master data (HD Data).
Classification Error item
Other service call ADI-HDD error: The generation of ADI authentication Admin Password
fails.
Check item Measures
Setting
Reinstall the system ROM data (OS Data).
Reinstall the master data (HD Data).
Check item Measures