EasyManua.ls Logo

Toshiba Tosvert VF-S15

Toshiba Tosvert VF-S15
394 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E6582175
K-13
11
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference

0331 Light-load high-
speed operation
switching lower
limit frequency
Hz 0.1/0.01 5.0-ul 40.0
6.21

0329 Light-load high-
speed learning
function
- - 0:No learning
1:Forward run learning
2:Reverse run learning
0

0330 Automatic light-load
high-speed
operation frequency
Hz 0.1/0.01 30.0-ul *1

0332 Light-load high-
speed operation
load waiting time
s 0.1/0.1 0.0-10.0 0.5

0333 Light-load high-
speed operation
load detection time
s 0.1/0.1 0.0-10.0 1.0

0334 Light-load high-
speed operation
heavy load
detection time
s 0.1/0.1 0.0-10.0 0.5

0335 Switching load
torque during
power running
% 1/0.01 -250- +250 50

0336 Heavy-load torque
during power running
% 1/0.01 -250- +250 100

0337 Heavy-load torque
during constant
power running
% 1/0.01 -250- +250 50

0338 Switching load
torque during
regenerative braking
% 1/0.01 -250- +250 50

0339 Factory specific
coefficient 3D
- - - -
* 3

0340 Creeping time 1 s 0.01/0.01 0.00-10.00 0.00
6.22.1

0341 Braking mode
selection
- -
0: Disabled
1: Forward winding up
2: Reverse winding up
3: Horizontal operation
0


0342 Load portion
torque input
selection
- -
0: Disabled
1: Terminal VIA
2: Terminal VIB
3: Terminal VIC
4: f343
4


0343
Hoisting torque bias
input (valid only
when =)
%
1/0.01
-250- +250 100


0344 Lowering torque
bias multiplier
%
1/0.01
0-100 100


0345
Brake release time
s
0.01/0.01
0.00-10.00 0.05


0346
Creeping frequency
Hz
0.1/0.01
f240 -20.0 3.0


0347
Creeping time 2
s
0.01/0.01
0.00-10.00 0.10


0348
Braking time
learning function
- 1/1
0:Disabled
1: Learning (0 after adjustment)
0

*1: Default setting values vary depending on the setup menu setting. Refer to section 11.5.
*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.