Example
The following example configures the following alarm conditions:
Alarm index — 1000
Sample interval — 360000 seconds
Rising threshold — 1000000
Falling threshold — 1000000
Rising threshold event index — 10
Falling threshold event index — 20 show rmon alarm-table
The show rmon alarm-table User EXEC mode command displays the alarms table.
Syntax
show rmon alarm-table
Default Configuration
This command has no default configuration.
Command Mode
User EXEC mode
User Guidelines
There are no user guidelines for this command.
Example
The following example displays the alarms table.
The following table describes significant fields shown above:
Console>
show rmon alarm-table
Index OID Owner
----- ---------------------- -------
1 1.3.6.1.2.1.2.2.1.10.1 CLI
2 1.3.6.1.2.1.2.2.1.10.1 Manager
3 1.3.6.1.2.1.2.2.1.10.9 CLI
Field Description
Index An index that uniquely identifies the entry.
OID Monitored variable OID.
Owner The entity that configured this entry.