BL20 - Communication in CANopen
D301087 0308 - BL20 CANopen4-56
Object 1010
hex
- Store Parameters
The object 1010
hex
can be used to save parameter changes in non-
volatile memory. The command is executed by writing the data
contents 0x6576 6173 ("save") to one of the Sub-indices.
Table 22:
Object 1010
hex
Object description
INDEX 1010
hex
Name Store parameters
Object code 3
hex
Data Type Unsigned32
Value description
Sub-index 00
hex
Description highest supported sub-index
Access ro
PDO-mapping No
Sub-index 01
hex
Description Save all parameters
Access rw
PDO-mapping No
Value range, BL20 Unsigned32
Default value, BL20 1
hex