BL20 - Communication in CANopen
D301087 0308 - BL20 CANopen4-270
Byte Design. Status
Comment
Byte 7,8 PKZ
ERR
Sx
Overcurrent protective circuit-breaker, slave x
Info field for the individual indication of the tripping a motor-
protective circuit-breaker (PKZ) as error message. If the
PKZ
INFO
A is set for single diagnostics, this bit field indicates the
error as soon as the PKZ of the slave Sx has tripped.
0 OK The PKZ of the slave has not tripped
or diag-nostics function has been
deactivated via the parameter setting.
1 tripped The PKZ of the slave has tripped.