SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R09

10V24 control and V25ter
Page 103 of 307
Type Syntax Response Example
OK OK
10.11.3î™–î™–î™–î™–Defined values
Parameter Type Description
<value> Number Range 1 to 255. The answer to the read command is in "xxx" format. The default and
the factory-programmed value is 43 (ASCII '+').
10.11.4î™–î™–î™–î™–Notes
SARA-R4 / SARA-N4
• The following table shows how the ATS2 command works for different data call scenarios.
Data call command L2 protocol Description ATS2 behavior
ATD*99***1# PPP PSD call: dial up Escape sequence
detection is only done for ~
+++. ATS2 is not effective.
There is not a timing
constraint (see the S12 AT
command) for ~+++ (++
+ is incapsulated in a PPP
frame)
ATD1234 CSD call The command is effective
if issued in both command
and online command mode
AT+USODL=0 PSD call: Direct Link mode The command is effective
AT+USOWR=0,32 PSD call:AT socket (not transparent) Break detection is not
supported
Table 8: ATS2 handling for different data call scenarios
SARA-R4 / SARA-N4
• The command has no effect.
10.12î™–î™–î™–î™–Command line termination character S3
S3
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial No Profile No - +CME Error
10.12.1î™–î™–î™–î™–Description
Sets a value representing the decimal IRA5 value of the character recognized by the DCE from the DTE,
to terminate the incoming command line. It is also generated by the DCE as part of the header, trailer and
terminator for result codes and information text, along with the S4 setting.
10.12.2î™–î™–î™–î™–Syntax
Type Syntax Response Example
Set ATS3=<value> OK ATS3=13
OK
Read ATS3? <value>
OK
013
OK
10.12.3î™–î™–î™–î™–Defined values
Parameter Type Description
<value> Number Range 0 to 127. The answer to the read command is in "xxx" format. The default and
the factory-programmed value is 13 (ASCII carriage return (CR, IRA5 0/13)).

Table of Contents

Other manuals for Ublox SARA-R4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ublox SARA-R4 Series and is the answer not in the manual?

Ublox SARA-R4 Series Specifications

General IconGeneral
BrandUblox
ModelSARA-R4 Series
CategoryControl Unit
LanguageEnglish

Related product manuals