EasyManua.ls Logo

Ublox SARA-R4 Series - 7.6 Network registration status +CREG

Ublox SARA-R4 Series
307 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R09
7Network service
Page 46 of 307
Parameter Type Description
8: LTE CAT-NB1
9: eGPRS
<PreferredAct> Number Indicates the preferred access technology; it is ignored if dual mode or tri mode are
not selected.
0: GSM
2: UTRAN
3: LTE
7: LTE CAT-M1
8: LTE CAT-NB1
9: eGPRS
<2ndPreferredAct> Number Indicates the second preferred access technology; it is ignored if tri mode is not
selected.
0: GSM
2: UTRAN
3: LTE
7: LTE CAT-M1
8: LTE CAT-NB1
9: eGPRS
7.5.4Notes
AT&T's EF
RAT
mode contains the RAT mode setting, the RAT mode setting is the mode that the module
shall be set to. Thus this setting may override +URAT's <SelectedAcT> and <PreferredAct> loaded at
boot time.
SARA-R404M / SARA-R410M-01B
<SelectedAcT>=0, 1, 2, 4, 5, 6, 7, 8, 9 are not supported. The factory-programmed value of <SelectedAcT>
is 3.
SARA-R410M-02B / SARA-R410M-52B
<SelectedAcT> is the first AcT the module will search. In the case a suitable cell can't be found on this
AcT, the module will search the <PreferredAct> if defined.
<PreferredAct> is the next AcT the module will search if no suitable cell can be found on the
<SelectedAcT>. In the case a suitable cell can't be found on this AcT, the module will search the
<2ndPreferredAct> if defined.
<SelectedAcT>=0, 1, 2, 3, 4, 5, 6, 9 are not supported. The factory-programmed value of <SelectedAcT>
is 7.
<PreferredAct>=0, 2, 3, 9 are not supported. The factory-programmed value of <PreferredAct> is 8.
<2ndPreferredAct>=0, 2, 3, 9 are not supported. The factory-programmed value of <PreferredAct> is
NULL.
SARA-N4
<SelectedAcT>=0, 1, 2, 3, 4, 5, 6, 7, 8, 9 are not supported. The factory-programmed value of
<SelectedAcT> is 8.
7.6Network registration status +CREG
+CREG
SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial No No No - +CME Error
7.6.1Description
Configures the network registration information. Depending on the <n> parameter value, a URC can be issued:
+CREG: <stat> if <n>=1 and there is a change in the MT's circuit switched mode network registration status
in GERAN/UTRAN/E-UTRAN
+CREG: <stat>[,<lac>,<ci>[,<AcTStatus>]] if <n>=2 and there is a change of the network cell in GERAN/
UTRAN/E-UTRAN

Table of Contents

Other manuals for Ublox SARA-R4 Series

Related product manuals