14System features
Page 160 of 307
14.11LWM2M configuration +UFOTACONF
+UFOTACONF
SARA-R410M-52BModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No NVM No - +CME Error
14.11.1Description
Configures the uFOTA registration and timer for periodic connections to the uFOTA server.
14.11.2Syntax
Type Syntax Response Example
Generic syntax
Set AT+UFOTACONF=<mode>,
<param>
OK AT+UFOTACONF=2,604800
OK
uFOTA registration
Set AT+UFOTACONF=1,<registration> OK AT+UFOTACONF=1,1
OK
uFOTA periodic connection
Set AT+UFOTACONF=2,<timer> OK AT+UFOTACONF=2,604800
OK
Read AT+UFOTACONF=<mode> +UFOTACONF: <mode>,<param>
OK
+UFOTACONF: 1,1
OK
Test AT+UFOTACONF=? +UFOTACONF: (list of supported
<mode>s),(list of supported
<param>s)
OK
+UFOTACONF: (1-2),(-1,1-
4294967295)
OK
14.11.3Defined values
Parameter Type Description
<mode> Number uFOTA parameter to be configured:
1: module registration to uFOTA server
2: timer for periodic connection to the uFOTA server
<registration> Number uFOTA registration:
0: module registration to uFOTA server disabled
1 (factory-programmed and default value): module registration to uFOTA server
enabled
<timer> Number Timer for periodic connection to the uFOTA server (in seconds); the factory-
programmed and default value is 604800 (7 days):
-1: never periodically connected to the uFOTA server
1-4294967295: range in seconds for periodic connections
<param> Number /
String
Type and supported content depend on the related <op_code> parameter; details are
given above