5Mobile equipment control and status
Page 31 of 307
Parameter Type Description
• "smsfull": indication that an SMS has been rejected with the cause of SMS storage
full
o 0: SMS storage not full
o 1: SMS storage full
• "gprs": PS indication status:
o 0: no PS available in the network
o 1: PS available in the network but not registered
o 2: registered to PS
o 65535: indication not available
• "callsetup": call set-up:
o 0: no call set-up
o 1: incoming call not accepted or rejected
o 2: outgoing call in dialling state
o 3: outgoing call in remote party alerting state
• "callheld": call on hold:
o 0: no calls on hold
o 1: at least one call on hold
• "simind": SIM detection
o 0: no SIM detected
o 1: SIM detected
o 2: not available
5.3.4î™–î™–î™–î™–Notes
• If the battery charging is not supported, "battchg" always returns 5 (full charge).
• The <descr> values cannot be changed with +CIND set.
• The following mapping of "signal" value to the power level exists:
"signal" value Power level
0 (< -105 dBm or unknown)
1 (< -93 dBm)
2 (< -81 dBm)
3 (< -69 dBm)
4 (< -57 dBm)
5 (>= -57 dBm)
5.4î™–î™–î™–î™–Configuration of indicator control +UCIND
+UCIND
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No No No - +CME Error
5.4.1î™–î™–î™–î™–Description
Allows the configuration of unsolicited results for indications with +CIEV.
5.4.2î™–î™–î™–î™–Syntax
Type Syntax Response Example
Set AT+UCIND=[<conf>] OK AT+UCIND=7
OK
Read AT+UCIND? +UCIND: <conf>
OK
+UCIND: 7
OK
Test AT+UCIND=? OK