Page #107 background imageLoading...
Page #107 background image
SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R09

10V24 control and V25ter
Page 107 of 307
10.19î™–î™–î™–î™–Escape prompt delay (EPD) S12
S12
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial No No No - +CME Error
10.19.1î™–î™–î™–î™–Description
Defines the maximum period, in fiftieths of a second, allowed between the reception of the last character of
the sequence of three escape characters from the DTE and the sending of the OK result code to the DTE. If any
characters are detected during this time, the OK will not be sent.
Furthermore, the timeout is:
• The minimum period, before the first character reception of the three escape character sequence, during
which no other character must be detected to accept it as a valid first character
• The maximum period allowed between receipt of first, or second, character of the three escape character
sequence and receipt of the next
• The minimum period, after the last character reception of the three escape character sequence, during
which no other character must be detected to accept the escape sequence as a valid one
10.19.2î™–î™–î™–î™–Syntax
Type Syntax Response Example
Set ATS12=<value> OK ATS12=80
OK
Read ATS12? <value>
OK
050
OK
10.19.3î™–î™–î™–î™–Defined values
Parameter Type Description
<value> Number Range 0 - 255. The answer to the read command is in "xxx" format. The default value
is 50 (1 s)
10.20î™–î™–î™–î™–Command echo E
E
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No Profile No - +CME Error
10.20.1î™–î™–î™–î™–Description
Controls whether or not the MT echoes characters received from the DTE during command state.
10.20.2î™–î™–î™–î™–Syntax
Type Syntax Response Example
Set ATE[<value>] OK ATE1
OK
10.20.3î™–î™–î™–î™–Defined values
Parameter Type Description
<value> Number
• 0: echo off
• 1 (default and the factory-programmed value): echo on

Table of Contents

Other manuals for Ublox SARA-R4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ublox SARA-R4 Series and is the answer not in the manual?

Ublox SARA-R4 Series Specifications

General IconGeneral
BrandUblox
ModelSARA-R4 Series
CategoryControl Unit
LanguageEnglish

Related product manuals