EasyManuals Logo
Home>Ublox>Control Unit>SARA-R4 Series

Ublox SARA-R4 Series User Manual

Ublox SARA-R4 Series
307 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #162 background imageLoading...
Page #162 background image
SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R09

14System features
Page 162 of 307
Parameter Type Description
Factory-programmed value: empty string.
<msg_format> Number Format of the <text> parameter. Allowed values:
• 0 (factory-programmed value): text
• 1: binary
<profile_id> Number PSD profile identifier. Only the value 1 is allowed.
<IP_protocol> Number IP protocol used for socket connection. Allowed values:
• 17: UDP
<IP_addr:PORT> String IPv4 or IPv6 server address with the socket port.
Factory-programmed value: empty string.
<method> Number Notification method, it is the way the application send out the <text message>.
Allowed values:
• 1: use IP (TCP or UDP) connection
<urc_enable> Number Flag determining if the URC is to be issued or not. Allowed values:
• 0: disabled
• 1 (factory-programmed value): enabled
<result> Number Operation result. Allowed values:
• 0: success
• 1: generic fail
<bearer> Number Notification used bearer. Allowed values:
• 1: IP (TCP or UDP) connection
<nv_upd_freq> Number NVM update frequency in seconds. Valid range of 0-3600 seconds indicating how
frequently to flush the settings to NVM. A zero value indicates that settings should
never be saved to NVM, otherwise the following settings will be saved to NVM based
on the timer: <GPIO_mode>, <text>, <IP_addr:PORT>, <urc_enable>, <tx_count>.
Factory-programmed value: 60.
<tx_count> Number Indicates the number of times to transmit the last gasp message. Valid range is 1-10.
Factory-programmed value: 1.
14.12.4î™–î™–î™–î™–Notes
SARA-R410M-52B / SARA-N4
• The <urc_enable>,<nv_upd_freq>,<tx_count> parameters will return 0, 0 and 0 if read for the first time
before setting the mandatory last gasp parameters. Once the mandatory last gasp parameters are set,
these values take on the factory-programmed values.

Table of Contents

Other manuals for Ublox SARA-R4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ublox SARA-R4 Series and is the answer not in the manual?

Ublox SARA-R4 Series Specifications

General IconGeneral
BrandUblox
ModelSARA-R4 Series
CategoryControl Unit
LanguageEnglish

Related product manuals