SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R09

9Short Messages Service
Page 78 of 307
Parameter Type Description
<alpha> String Alphanumeric representation of <da> or <oa> corresponding to the entry found in the
phonebook 3GPP TS 24.008 [12]. The parameter is not managed.
<scts> String Service center time stamp in time-string format; see the <dt> parameter
<tooa> Number Type of address of <oa> - octet
<length> Number Two meanings:
• in text mode: number of characters
• in PDU mode: PDU's length in octets without the Service Center's address. In
example 039121430100038166F6000004E374F80D: this is a PDU with Service
Center's number +1234, that generates the address 03912143 (4 octets). Thus in
this case <length> = 13.
<data> String This is the TP-User-Data in text mode; the decoding depends on the DCS (Data
Coding Scheme) and the FO (First Octect) of the SMS header 3GPP TS 23.040 [8];
format:
• if DCS indicates that 3GPP TS 23.038 [7] GSM 7 bit default alphabet is used and FO
indicates that 3GPP TS 23.040 [8] TP-User-Data-Header-Indication is not set:
o if TE character set other than "HEX" (see the +CSCS AT command description):
ME/TA converts GSM alphabet into current TE character set according to rules
of Annex A
o if TE character set is "HEX": ME/TA converts each 7-bit character of GSM
7 bit default alphabet into two IRA character long hexadecimal number (e.g.
character Æ (GSM 7 bit default alphabet 28) is presented as 1C (IRA 49 and 67))
• if DCS indicates that 8-bit or UCS2 data coding scheme is used, or FO indicates that
3GPP TS 23.040 [8] TP-User-Data-Header-Indication is set: ME/TA converts each
8-bit octet into two IRA character long hexadecimal number (e.g. octet with integer
value 42 is presented to TE as two characters 2A (IRA 50 and 65))
In the case of CBS: 3GPP TS 23.041 [9] CBM Content of Message in text mode
responses; format:
• if DCS indicates that 3GPP TS 23.038 [7] GSM 7 bit default alphabet is used:
o if TE character set other than "HEX" (see the +CSCS AT command description):
ME/TA converts GSM alphabet into current TE character set according to rules
of Annex A
o if TE character set is "HEX": ME/TA converts each 7-bit character of the GSM 7
bit default alphabet into two IRA character long hexadecimal number
if DCS indicates that 8-bit or UCS2 data coding scheme is used: ME/TA converts each
8-bit octet into two IRA character long hexadecimal number
<da> String Destination address
<toda> Number Type of address of <da> - octet
<fo> Number First octet of the SMS TPDU (see 3GPP TS 23.040 [8])
<mr> Number Message reference
<ra> String Recipient address field
<tora> Number Type of address of <ra> - octet
<dt> String Discharge time in format "yy/MM/dd,hh:mm:ss+zz"; the time zone is expressed in
steps of 15 minutes. The range goes from -48 to +56
<st> Number Status of an SMS STATUS-REPORT
<ct> Number TP-Command-Type (default 0)
<sn> Number CBM serial number
<mid> Number CBM message identifier
<page> Number 3GPP TS 23.041 [9] CBM Page Parameter bits 4-7 in integer format
<pages> Number 3GPP TS 23.041 [9] CBM Page Parameter bits 0-3 in integer format
<pdu> String Protocol data unit: each 8-bit octet is presented as two IRA character long
hexadecimal numbers, e.g. octet with integer value 42 is presented to TE as two
characters 2A (IRA 50 and 65)
<dcs> Number Data Coding Scheme

Table of Contents

Other manuals for Ublox SARA-R4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ublox SARA-R4 Series and is the answer not in the manual?

Ublox SARA-R4 Series Specifications

General IconGeneral
BrandUblox
ModelSARA-R4 Series
CategoryControl Unit
LanguageEnglish

Related product manuals