Type Syntax Response Example
URC +CRTDCP: <cid>,<cpdata_length>,
<cpdata>
+CRTDCP: 0,2,"ab"
9.23.3î™–î™–î™–î™–Defined values
Parameter Type Description
<reporting> Number
• 0 (default value): reporting disabled
• 1: reporting enabled by means of the URC +CRTDCP
<cid> Number See <cid>
<cpdata_length> Number Size of the received data. The maximum length 512 bytes
<cpdata> String User data container content (see the 3GPP TS 24.301 [88] subclause 9.9.4.24)