Document Number: WS21002 119
Document Title: WSII Operations Manual
The current configuration of the Wash Select II only allows one coin to be dispensed at a
time. Therefore, if you would like to dispense the dollar coin, it will be necessary to make
changes to the coin hopper.
3.5.1 Programming the IDX Acceptor

Note:
When inserting coins into the IDX, you must be sure to close the cover completely.
The unit comes equipped to accept both U.S. quarters and dollar coins, and will dispense
quarters by default. The unit will also accept site-specific tokens. This section will guide you
through the programming of each of the site-specific coins that will be accepted and give
details on erasing this program, if a programming error ever occurs.
In order to complete the programming you must have six of each of the tokens and coins you
wish to accept. It is very important that you follow these directions exactly. The IDX acceptor
will average the variances in these different sample coins during programming, and calculate
a more accurate reference model. Using less than six different coins will invalidate the
average variance generated by this process.
Please refer to the block diagrams shown in Figure 23 while programming the IDX coin
acceptor.

Table of Contents

Other manuals for Unitec Wash Select II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unitec Wash Select II and is the answer not in the manual?

Unitec Wash Select II Specifications

General IconGeneral
BrandUnitec
ModelWash Select II
CategoryTouch terminals
LanguageEnglish