2DA/2DB
1-6-1
1-6-1 Precautions for assembly and disassembly
(1) Precautions
Be sure to turn the power switch off and disconnect the power plug before starting disassembly.
•When handling PCBs, do not touch connectors with bare hands or damage the board.
Do not touch any PCB containing ICs with bare hands or any object prone to static charge.
Use only the specified parts to replace the fixing unit thermostat. Never substitute electric wires, as the MFP may be
seriously damaged.
Use the following testers when measuring voltages:
Hioki 3200
Sanwa MD-180C
Sanwa YX-360TR
Beckman TECH300
Beckman DM45
Beckman 330*
Beckman 3030*
Beckman DM850*
Fluke 8060A*
Arlec DMM1050
Arlec YF1030C
* Capable of measuring RMS values.
Prepare the following as test originals:
1. NTC (new test chart)
2. NPTC (newspaper test chart)