Partset
Exit/Entry
Tick the relevant checkbox to change the behaviour of entry/exit zones to alarm zones when in
Partset A or B mode. This feature is useful for a domestic installation when the system has been
set in partset mode. If the user partsets the system at night he/she may wish the alarm to activate
immediately if the front or back door is opened during the night.
Partset
Local
Tick the relevant checkbox to restrict the reporting of alarms in Partset Mode to local reporting only
(No remote reporting).
No Bells If ticked, no bells will be activated for partset A or B.
Linked Areas
This section enables you to link areas for setting and unsetting purposes:
Fullset Fullset this area when all linked areas are Fullset.
Fullset All Fullset all areas when this area is Fullset.
Prevent Fullset Prevent this area from Fullset if all linked areas are Fullset.
Prevent Fullset All Prevent linked areas from Fullset if this area is not Fullset.
Unset Unset this area when all linked areas are Unset.
Unset All Unset all areas when this area is Unset.
Prevent Unset Prevent this area from Unset if any linked areas are Fullset.
Prevent Unset All Prevent linked areas from Unset if this area is Fullset.
Authorise Setting Enable authorised setting for linked areas. Refer Authorised Setting of the Blocking Lock.
Linked Areas Click the areas that you wish to link to this area.
Schedule
Configure scheduling with the following settings:
Calendar Select a calendar to control scheduling.
Unset Select if area should automatically Unset as per the time specified in the selected calendar.
Fullset Select this option to Fullset the area as per the time specified in the selected Calendar. The area will
also set when the Unset Duration or Delay Interval has elapsed (see Setting/Unsetting on page275). If
the Unset Duration overlaps the scheduled time, the area will use the calendar settings.
Time
Locked
Select this option to time lock the area as per the selected Calendar. (Vault type area in Financial mode
only)
Vault
Access
Enter the number of minutes (0–120) to activate this timer at the end of a Time Locked Unset period. If
the area is not unset after this timer expires, the area cannot be unset until the start of the next Time
Locked Unset period. (Vault type area in Financial mode only)
Reporting
The Reporting configuration settings are applicable for Standard Areas in Commercial and Financial
installations only and are only relevant if a calendar has been selected. (See Schedule above.)
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2018 273 A6V10276959-d
11.2018

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPCA210.100 and is the answer not in the manual?

Vanderbilt SPCA210.100 Specifications

General IconGeneral
BrandVanderbilt
ModelSPCA210.100
CategoryPower Supply
LanguageEnglish

Related product manuals