BA 357-00 * 3.0 * 35700_05_Bedienung.fm 5-111
Operation 5
Activities in preparation for decommissioning
1. Charge the battery.
2. Clean the machine thoroughly.
3. Lower the loader unit completely and set the attachment horizontally
with the ground.
4. Set the drive to a neutral position
– see "Slowing the machine and stopping" on page 5-15.
5. Apply the parking brake – see "Parking brake" on page 5-6.
6. Actuate the motor isolating switch.
7. Park the machine and remove the ignition key.
➥ The immobilizer (opt) is enabled.
8. Close and safely lock the cabin doors and windows.
9. Disconnect the battery connector from the vehicle connection only
when parked for over 2 weeks
– see chapter 4 “Disconnecting the battery connector” on page 4-21.
10.Take additional measures to secure the machine by placing chocks
under the downhill sides of the wheels.
Activities during decommissioning
1. During decommissioning, depending on the storage temperature, the
battery must be regularly controlled.
The battery may be charged a maximum
of 4 times in a period of 24 months.
2. Keep the surface of the battery clean, to avoid leakage currents.
Storage temperature Measure
-15 to 0 °C (5 to 32 °F)
➥ Connect the battery for trickle
charging permanently to the battery
charger.
Over 0°C (32°F)
➥ Measure the off-load voltage of the
battery every three months. If the
value falls below 84 V, then the
battery must be recharged.
1
1. At storage temperature above 30 °C, the intervals of time between measurements must be cut in half.