Problem Possible cause Remedy
No information in display No operating voltage Insert fuse,
check power supply
"Fault" display in heading. Additional details
in fault table
Open fault table and read out cause Inform specialist dealer if necessary
Uncontrolled movements of the connected
products
Temporary power failure A power failure must be followed by a cali-
bration
Product cannot be operated with the control
panel
Fine-wire fuse in actuator faulty (local op-
eration not working either)
Examine fault causes and remedy them
Safety function active (local operation is not
working either)
Wait until the cause (precipitation, wind,
ice) is no longer present
Wind test identified fault Reset wind test
Wisotronic does not respond to an EWFS
Hand-held transmitter
Transmitter has not been learned in Lean in sensor
Wrong channel was selected for 8-channel
EWFS transmitter
Select the right channel and repeat the
move command
Button press too short Repeat command
Interfering ambient influences Reduce distance to Wisotronic
Safety function active Wait until the cause (precipitation, wind,
ice) is no longer present
Wind test identified fault Reset wind test
Wisotronic responds only sporadically to an
EWFS Hand-held transmitter
Interfering ambient influences Reduce distance to Wisotronic
Interference through external transmitter Switch off external transmitter (e.g. Baby-
phone)
Batteries of EWFS transmitter are weak Change the batteries
Control functions do not respond Control functions are deactivated on the
control panel
Activate control functions in the main menu
and in the comfort functions
Control functions is disabled through ab-
sence function or leave
Safety function active (local operation is not
working either)
Control functions do not respond as re-
quired
Incorrect sensor allocation Check settings
A wind alarm is triggered even in a gentle
wind
The wind speed limit is set too low Increase wind limit value, observe safety
instructions
No wind alarm is triggered even in a strong
wind
The wind speed limit is set too high Decrease wind limit value, observe safety
instructions
Wind monitoring is switched off Switch on wind monitoring