890557_d•en•01.07.2014
We reserve the right to carry out improvements
40
Wisotronic 1-channel
Operating instructions
7.2.1.7 Delay CLEAR
To prevent a sun shading product from being lowered or the slats from being
tilted up immediately at each brightness change (e.g. when the cloud cover
temporarily increases), a delay time can be assigned to the “Clear” limit
value. This quiets the motion behaviour of the sun shading product, thereby
increasing the level of comfort. If the values reach or drop below the limit
values for the duration of this delay time, the sun shading product moves and
the slats are tilted up. The setting range is 0...99 minutes.
Turn the touchwheel to set the "CLEAR" limit value.
The [Stand.] function button sets the "CLEAR" delay to the factory setting.
OTEN Simply set the delay time to “0 min.” to deactivate the delay.
7.2.1.8 Position CLEAR
The “CLEAR” position value specifies the position to which the sun shad-
ing product is to move when the sky is clear. The setting range is 0-100%; a
value of 0% corresponds to the upper limit position and a value of 100% to
the lower limit position.
If you do not want to trigger any movement during a clear sky,
the function button [---] leaves the “Position CLEAR” unchanged.
Turn the touchwheel to set the limit value “Position CLEAR”.
The function button [Stand.] sets the product-specific factory setting.
7.2.1.9 Slat angle CLEAR
This setting is required when you have chosen a slat product as channel
type (external or internal venetian blinds). If you have connected a slat prod-
uct (such as an external venetian blind), you can specify how the slats are
to be set after the movement to the “CLEAR” position has been completed.
This is especially useful if you prefer a specific setting. In addition, you
do not have to tilt the slats up after automatic movement. The sun control
automatically tilts up the slats if programmed accordingly. The factory set-
ting for the slat position with automatic operation is +0° (= horizontal, see
Chapter 7.2.1.5 on page 38).
Turn the touchwheel to set the value “Slat angle CLEAR”.
The function button [---] leaves the slat angle unchanged, function button
[Stand.] sets the value for position “Clear” to 0° (factory setting).
7.2.1.10 Limit value CLOUD
The "CLOUD" limit value specifies the brightness at which the sun shading
products of a channel is to be raised. The setting range is 1-100 klx.
To set the limit value “CLOUD”, turn the touchwheel (the value increases or
reduces depending on the direction of rotation).
The function button [---] deactivates assessment; the function button
[Stand.] sets the limit value “CLOUD” depending on the product (factory set-
ting).
Sun control