15 Technical data
Wisotronic 1-channel Min. Typ. Max. Unit
Supply
Operating voltage 85 230 265 V AC
Frequency 50 60 Hz
Power consumption < 1 5 W
Floating output
Switching capacity per channel
at 230V AC/cos ϕ 0.6
500 VA
Switching capacity per channel
at 24V DC
72 W
Fuse protection per channel 3.15 AT
Internal temperature sensor
Measuring range 0 50 °C
Miscellaneous
Automatic operation Type 1
Software class A
Display Graphic display, 240 x 320 pixels
Program user guidance Menu-guided text display
Program entry 4 capacitive buttons/touchwheel
HF receiver
Receiving frequency ASK
(OOK)
433.92 MHz
Range
(environment without interfer-
ence)
30 m
Enclosure
Dimensions H×W×D 177 × 97 × 5
Degree of protection IP40
Safety class II
Location of use Clean ambient conditions
Test standards
DIN EN 60730-1:2005-12
DIN EN 61000-6-2:2006-03
DIN EN 61000-6-3:2007-09
DIN EN 50366:2006-11
EN 300220-3:2001-03
EN 301489-3:2002-08
Connection
Control panel Plug-and-socket connection
Power unit Spring terminals
Miscellaneous
Conformity
Available at http://www.warema.de
Ambient conditions
Operating temperature 0 20 40 °C
Storage temperature 0 20 50 °C
Rel. humidity
(non-condensing)
10 40 85 %RH