890557_d•en•01.07.2014 We reserve the right to carry out improvements
97
7.9.2 Ice monitor
The ice monitoring safety function prevents destruction of your sun shading
products through movements when, for example, the guide rails are frozen.
An ice alarm can be reset automatically and/or manually.
Press the function button [Sett.] in the main menu and go to the
[Safety functions] > [Ice monitor] menu.
The following view appears in the display (the header may show the channel
name you selected instead of Channel 1 and the setting values in the right
column may be different:
7.9.2.1 Automatic reset ice alarm?
In this menu line, you specify whether the ice monitor is to reset an ice alarm
automatically. The automatic comfort controls and the manual operation are
enabled again when the conditions for an ice alarm no longer exist.
Set or delete the checkmark in the line [Reset ice alarm automatically]
to activate or deactivate the automatic reset of an ice alarm.
NOTE To ensure that the product is not damaged, the ice alarm is not reset until the
outside temperature is 2°C above the preset [Limit value ICE].
Start menu
Main menu
Settings
Safety functions
Ice monitor
Safety functions