3.5 Set Pulse Equivalent
During commissioning, you need to modify pulse equivalent according to the actual
situation first before controlling the machine tool.
To set pulse equivalent, do the following:
1. To enter the menu interface, press .
2. To enter the interface of manufacturer parameters, select 5. Mfr Param by
pressing / , and press .
3. To check pulse equivalent, select 3. Pulse Equiv. by pressing /
, and press :
4. To modify pulse equivalent, input the value with the handheld box and press
. The prompt The parameters are modified. Restart? appears.
5. To validate the modification, press . NK105 automatically restarts.