9.2.5 Tool Change Travel
Strk Upper Lmt
Unit: mm
Range: [Lower Limit of Tool Change, 67108.864]
Default value: 400
Effective: Immediately
Description: The machine coordinate of upper limit of workbench travel during
tool change.
Strk Lower Lmt
Unit: mm
Range: [-67108.864, 67108.864]
Default value: -100
Effective: Immediately
Description: The machine coordinate of lower limit of workbench travel during
tool change.
9.2.6 Travel Limit
Travel Limit
Unit: -
Range: Yes; No
Default value: No
Effective: Immediately
Description: Whether to enable travel limit of each axis.
9.2.7 Machine Origin
REFP Speed
Unit: mm/min
Range: [0.001, Max Speed]
Default value: -
Effective: Immediately
Description: The speed of coarse positioning during returning to machine
origin.