上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
78 / 97
9.2.5 Tool Change Travel
Strk Upper Lmt
• Unit: mm
• Range: [Lower Limit of Tool Change, 67108.864]
• Default value: 400
• Effective: Immediately
• Description: The machine coordinate of upper limit of workbench travel during
tool change.
Strk Lower Lmt
• Unit: mm
• Range: [-67108.864, 67108.864]
• Default value: -100
• Effective: Immediately
• Description: The machine coordinate of lower limit of workbench travel during
tool change.
9.2.6 Travel Limit
Travel Limit
• Unit: -
• Range: Yes; No
• Default value: No
• Effective: Immediately
• Description: Whether to enable travel limit of each axis.
9.2.7 Machine Origin
REFP Speed
• Unit: mm/min
• Range: [0.001, Max Speed]
• Default value: -
• Effective: Immediately
• Description: The speed of coarse positioning during returning to machine
origin.