上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
79 / 97
REFP Dir
• Unit: -
• Range: Positive; Negative
• Default value: -
• Effective: Immediately
• Description: The direction of coarse positioning during returning to machine
origin.
Retract Dist
• Unit: mm
• Range: [0,10000]
• Default value: -
• Effective: Immediately
• Description: The additional motion distance after fine positioning during
returning to machine origin.
9.2.8 Spindle
ON/OFF Delay
• Unit: ms
• Range: [0, 60000]
• Default value: 5000
• Effective: Immediately
• Description: The waiting time for the spindle to reach normal speed or
completely stop after turning on/off spindle.
Spindle Speed
• Unit: r/min
• Range: [0, Max Spindle Speed]
• Default value: 10000
• Effective: Immediately
• Description: The spindle speed.
Max Spdl Speed
• Unit: r/min
• Range: [0, 999999]
• Default value: 24000
• Effective: Immediately
• Description: The maximum spindle speed.