9.1.8 Stopping the Spindle
SOFF at Pause
Unit: -
Range: Yes ; No
Default value: Yes
Effective: Immediately
Description: Whether to stop the spindle when machining pauses.
SOff at Stop
Unit: -
Range: Yes ; No
Default value: Yes
Effective: Immediately
Description: Whether to stop the spindle when machining stops.
SOff at End
Unit: -
Range: Yes ; No
Default value: Yes
Effective: Immediately
Description: Whether to stop the spindle when machining ends.
9.1.9 Override
Ration ON MANU
Unit: -
Range: Yes ; No
Default value: No
Effective: Immediately
Description: Whether the feedrate of manual operations is adjusted by the
override.
Ration ON Jigg
Unit: -
Range: Yes ; No
Default value: Yes
Effective: Immediately
Description: Whether the feedrate of fine adjustment is adjusted by the
override.