Item Function Effect
014 Index button Opens the INDEX page
015 Print button Makes a screenshot of the current screen, refer to section
6.8.31 LDU-20 page - SCREENSHOT
016 Transfer Mode status Shows the transfer mode status:
•
High BN
•
Low BN
•
Transferring
•
Transfer interlock
017 Sulfur Content Shows the sulfur content of the fuels related to the settings in
the RCS
NOTE: Here you only can change these values, if the RCS
has failed.
018 Force Transfer button Starts a transfer (only applicable if a transfer is interlocked)
NOTE: An interlock is active, if the related cylinder oil pres-
sure is too low. Use this button only, if you are sure
to override the interlock.
X92DF
AA00-9606-09AAA-043B-A
Operation Manual LDU-20 page - iCAT
Winterthur Gas & Diesel Ltd.
- 316 - Issue 002 2020-08