10 Stop the control system from the engine as follows:
10.1 Set to OFF all circuit breakers in the power supply box E85.
10.2 Set to OFF the engine control system (ECS) and the remote control system
(RCS).
11 Do a check of the rail unit as follows:
11.1 Open the covers.
11.2 Make sure that there is no condensation or corrosion.
11.3 If you find condensation or corrosion, do the steps that follow:
11.3.1 Clean the related part.
11.3.2 Find the cause and repair the fault.
11.4 If necessary, apply anti-corrosion oil to give protection.
11.5 Close the covers.
12 Do a check of the supply unit as follows:
12.1 Make sure that there is no condensation or corrosion.
12.2 If you find condensation or corrosion, do the steps that follow:
12.2.1 Clean the related part.
12.2.2 Find the cause and repair the fault.
12.3 If necessary, apply anti-corrosion oil to give protection.
13 If the engine must have preservation for a long period, speak to or send a message to
WinGD for the applicable preservation procedures.
CLOSE UP
• None
X92DF
AA00-0000-00AAA-151B-A
Operation Manual Prepare the engine for standstill maintenance
Winterthur Gas & Diesel Ltd.
- 485 - Issue 002 2020-08