PROCEDURE
1 Do a check of the level switch LS3444A (if applicable also LS3445A) for free flow. If
necessary, clean the bore of the pipe of the level switch.
2 Carefully look into the rail unit to find the cause of the leakage.
NOTE: Possible causes can be a defective pipe to the exhaust valve, a defective
flange or an other defective item.
3 Repair the defective item.
CLOSE UP
• None
X92DF
AA00-0000-00AAA-311E-A
Operation Manual Examine the rail unit for leakage
Winterthur Gas & Diesel Ltd.
- 541 - Issue 002 2020-08