1 Stop the engine.
2 Loosen the screws of the flange (008, Figure 10-12), but do not loosen one of the two
middle screws.
3 Turn the flange (008) to close the exhaust waste gate.
4 Tighten the screws to attach the flange (008).
5 Start the engine.
CLOSE UP
None
X92DF
AA00-8135-00AAA-662A-A
Operation Manual Temporary isolate the exhaust waste gate
Winterthur Gas & Diesel Ltd.
- 568 - Issue 002 2020-08