January 2016
2-48
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
07-220, 320, 420, 07-230, 330, 430
Status Indicator RAPs
• Tray feed assembly, PL 8.10 Item 1.
• Tray PWB, PL 7.20 Item 6.
13. Perform the OF5 Main PWB Check RAP.
4250/4260/4265 With an HCF
Refer to Wiring Diagram 31. Perform the following:
1. Make sure the HCF tray is fully home.
2. Pull out the HCF tray. Check for obstructions behind the tray.
3. Check that the HCF tray home position sensor actuator on the back of the HCF tray is not
missing or damaged.
4. Enter dC330 code 07-300. Check the HCF tray home sensor (Q07-300), PL 7.60 Item 1.
5. Check the wiring between the HCF tray home position sensor and CN6 on the HCF PWB.
If necessary, install a new HCF tray home sensor, PL 7.60 Item 1.
6. Manually lower, then raise the feed head link arm, PL 7.60 Item 15. Check that the feed
head, PL 8.10 Item 5 moves freely. Check that the actuator on the feed head actuates the
tray 1 up limit switch, PL 8.10 Item 17.
7. Check the tray 1 up limit switch, PL 8.10 Item 17.
NOTE: There is not a component control code for the tray 1 up limit switch.
8. Check the wiring between the tray up limit switch and CN7 on the HCF PWB.
9. If necessary, install a new tray 1 feed assembly, PL 8.10 Item 1.
10. If necessary, install a new HCF PWB, PL 7.60 Item 7.
07-230, 330, 430 Jam 0 From Tray 2, 3, 4 or HCF RAP
07-230 The lead edge of the paper failed to actuate the registration sensor within the correct
time after paper was fed from tray 2.
07-330 The lead edge of the paper failed to actuate the registration sensor within the correct
time after paper was fed from tray 3 or HCF.
07-430 The lead edge of the paper failed to actuate the registration sensor within the correct
time after paper was fed from tray 4.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
NOTE: The side cover assembly interlock switch must be closed to supply +24V to the motors
and clutches.
Go to the relevant procedure:
• 4150 and 4250/4260/4265 Without an HCF
• 4250/4260/4265 With an HCF
4150 and 4250/4260/4265 Without an HCF
NOTE: Trays 2, 3 and 4 are identical. Check the relevant tray module.
Refer to:
• (4150) Wiring Diagram 7, Wiring Diagram 12 and Wiring Diagram 13.
• (4250/4260) Wiring Diagram 12, Wiring Diagram 13 and Wiring Diagram 24.
• (4265) Wiring Diagram 12, Wiring Diagram 13 and Wiring Diagram 40.
Perform the following:
1. Pull out the tray. Remove all jammed paper.
2. Open the tray access door, PL 7.20 Item 18. Remove all jammed paper.
3. Check the paper path for damage or obstructions.
4. Check that the registration sensor actuator, PL 8.15 Item 5 moves freely and is not dam-
aged. If necessary, install a new registration sensor actuator assembly, PL 8.15 Item 14.
5. Enter dC330 code 08-500. Check the registration sensor (Q08-500), PL 8.15 Item 8.
6. (4150) Check the wiring between the registration sensor and CN13 on the Main PWB. If
necessary, install a new registration sensor, PL 8.15 Item 8.
7. (4250/4260) Check the wiring between the registration sensor and CN12 on the Main
PWB. If necessary, install a new registration sensor, PL 8.15 Item 8.
8. (4265) Check the wiring between the registration sensor and CN27 on the Main PWB. If
necessary, install a new registration sensor, PL 8.15 Item 8.
9. Check that the tray feed sensor actuator, PL 7.25 Item 16 moves freely and is not dam-
aged.
10. Enter dC330. Check the relevant tray feed sensor, PL 7.25 Item 14:
• Tray 2. Code 08-200.
• Tray 3. Code 08-300.