WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
04-100
Status Indicator RAPs
04-100 Tray 1 Elevating Error RAP
04-100 The tray 1 stack height sensor did not actuate within 13 seconds of the tray 1 elevating
motor start.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
NOTE: The main PWB has test points. The location of the test points is shown on the following
PJ location illustrations:
4150 Main PWB.
4250/4260 Main PWB.
4265 Main PWB
Refer to:
(4150) Wiring Diagram 6.
(4250/4260) Wiring Diagram 25.
(4265) Wiring Diagram 41
Perform the following:
1. Make sure tray 1 is fully home.
2. Pull out tray 1. Check for obstructions behind the tray.
3. Check the tray elevator mechanism on the back of tray 1.
4. Check that the tray 1 stack height sensor actuator on the feed head, PL 8.10 Item 5 is not
missing or damaged. If necessary, install a new tray 1 feed assembly, PL 8.10 Item 1.
5. Enter dC330 code 07-150. Check the tray 1 stack height sensor (Q07-150), PL 8.10 Item
2.
6. (4150) Check the wiring between the tray 1 stack height sensor and CN19 on the Main
PWB. If necessary, install a new tray 1 stack height sensor, PL 8.10 Item 2.
7. (4250/4260) Check the wiring between the tray 1 stack height sensor and CN15 on the
Main PWB. If necessary, install a new tray 1 stack height sensor, PL 8.10 Item 2
8. (4265) Check the wiring between the tray 1 stack height sensor and CN19 on the Main
PWB. If necessary, install a new tray 1 stack height sensor, PL 8.10 Item 2
9. (4150) Check the tray 1 up limit switch, PL 8.10 Item 17.
NOTE: There is not a component control code to check the up limit switch.
10. Enter dC330 code 04-510. Check the tray 1 elevating motor (MOT04-510), PL 7.15 Item
8.
11. (4150) Check the wiring between the tray 1 up limit switch and the tray 1 elevating motor,
PL 7.15 Item 8 and CN19 on the Main PWB.
12. (4250/4260) Check the wiring between the tray 1 up limit switch and the tray 1 elevating
motor, PL 7.15 Item 8 and CN15 on the Main PWB.
13. (4265) Check the wiring between the tray 1 up limit switch and the tray 1 elevating motor,
PL 7.15 Item 8 and CN19 on the Main PWB.
14. If necessary, install new components:
Tray 1 elevating motor, PL 7.15 Item 8.
Tray feed assembly, PL 8.10 Item 1.
Tray 1 cassette assembly, PL 7.10 Item 1.
15. Perform the OF5 Main PWB Check RAP.