EasyManua.ls Logo

Xinje XD5 - Page 282

Xinje XD5
389 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
281
S3+32
Sampling variation of
inflection point
Sampling difference between two
inflection points
-2147483648~2147483647
Internal usage
parameters of the
system
S3+34
Sampling interval time
of inflection point EK
04294967296 (unit: ms)
Internal usage
parameters of the
system
S3+36
Time from auto-tuning
PID to inflection point
04294967296 (unit: ms)
Internal usage
parameters of the
system
S3+38
Last sampling
temperature
-32767~32767
Internal usage
parameters of the
system
S3+39
The time from auto-
tuning PID operation to
inflection point
-32767~32767 (unit: ms)
Internal usage
parameters of the
system
S3+40
Starting sampling value
of auto-tuning PID
operation
-32767~32767
Internal usage
parameters of the
system
S3+41
Number of times at
inflection point during
auto-tuning
0~65535
Internal usage
parameters of the
system
S3+42
Useless time
04294967296 (unit: ms)
Internal usage
parameters of the
system
S3+44
Stop temperature
Temperature at the end of auto-
tuning
Range: -32767~32767
Internal usage
parameters of the
system
Critical oscillation part (read only parameters, only for monitoring)
S3+24
PID control mode
0: PID control
1: PI control
2: P control
16-bit no sign,
internal usage
parameters of the
system
S3+25
Current auto-tuning
segment
0: Preparation stage
1: start to auto tune
23: auto-tuning parameter
collection
4: calculation of PID parameters
16-bit no sign,
internal usage
parameters of the
system
S3+26
The auto-tuning
temperature is located
at the number of peaks
0: first peak
1: second peak
16-bit no sign,
internal usage
parameters of the
system
S3+27
The lowest sampling
temperature
-3276732767
Internal usage
parameters of the
system
S3+28
The highest sampling
temperature
-3276732767
Internal usage
parameters of the
system
S3+30
sampling time of the
lowest sampling
temperature
04294967296 (unit: ms)
Internal usage
parameters of the
system
S3+32
sampling time of the
highest sampling
temperature
04294967296 (unit: ms)
Internal usage
parameters of the
system

Table of Contents

Related product manuals