RPT SHIFT(28MHz)
Function: Sets the RPT offset frequency on the
28MHz band.
Available Values: 0 - 1000kHz
Default Setting: 100kHz
Description: The RPT o󰀨set frequency can be set
at 10kHz increments between 0kHz
and 1000kHz.
RPT SHIFT(50MHz)
Function: Sets the RPT offset frequency on the
50MHz band.
Available Values: 0 - 4000kHz
Default Setting: 1000kHz
Description: The RPT o󰀨set frequency can be set
at 10kHz increments between 0kHz
and 4000kHz.
ENC/DEC
Function: Selects the Tone Encoder and/or De-
coder mode.
Available Values: OFF / ENC / TSQ
Default Setting: OFF
Description:
ENC: CTCSS Encoder
TSQ: CTCSS Encoder/Decoder
TONE FREQ
Function: Setting of the CTCSS Tone Frequency.
Available Values: 50 standard CTCSS tones
Default Setting: 100.0Hz
RADIO SETTING
- MODE PSK/DATA -
AF TREBLE GAIN
Function: Sets the amount of gain in the treble
range of the received audio.
Available Values: -20 to +10
Default Setting: 0
Description: The amount of gain in the treble
range can be set in the range of -20
to +10.
AF MIDDLE TONE GAIN
Function: Setting the amount of gain in the mid-
dle range of the received audio.
Available Values: -20 to +10
Default Setting: 0
Description: The amount of gain in the middle
range can be set in the range of -20
to +10.
AF BASS GAIN
Function: Setting the amount of gain in the bass
range of the received audio.
Available Values: -20 to +10
Default Setting: 0
Description: The amount of gain in the bass
range can be set in the range of -20
to +10.
AGC FAST DELAY
Function: Sets the AGC-FAST DELAY voltage
decay characteristics for PSK/DATA
mode.
Available Values: 20 - 4000msec
Default Setting: 160msec
Description: Sets the AGC voltage decay char-
acteristics in 20msec steps after the
input signal level becomes lower
than the AGC detection level and the
HOLD time has expired.
AGC MID DELAY
Function: Sets the AGC-MID DELAY voltage
decay characteristics for PSK/DATA
mode.
Available Values: 20 - 4000msec
Default Setting: 500msec
Description: Sets the AGC voltage decay char-
acteristics in 20msec steps after the
input signal level becomes lower
than the AGC detection level and the
HOLD time has expired.