9.19 Defaults by Bypass and Drive Model
692 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
No. Name Unit Default
-
Bypass
Model
-
B001
B002
B003
B004
B007 B011 B014 B021 B027 B034 B040
o2-04
Drive Model
(KVA)
Selection
Hex. 95 97 99 9A 9B 9D 9E 9F
E2-11
Motor Rated
Power
HP
(kW)
2
(1.5)
4
(3.0)
5
(4.0)
7.5
(5.5)
10
(7.5)
15
(11)
20
(15)
25
(18.5)
n1-01
Hunting
Prevention
Selection
- 1 1 1 1 1 1 1 1
n1-03
Hunting
Prevention
Time Constant
ms 10 10 10 10 10 10 10 10
No. Name Unit Default
-
Bypass
Model
- B052 B065 B077 B096 B124 B156 B180 B240 B302
o2-04
Drive
Model
(KVA)
Selection
Hex. A0 A2 A3 A4 A5 A6 A7 A8 A9
E2-11
Motor
Rated
Power
HP
(kW)
30
(22)
40
(30)
50
(37)
60
(45)
75
(55)
100
(75)
125
(90)
150
(110)
200
(160)
b3-04
V/f Gain
during Speed
Search
% 100 100 100 100 80 60 60 60 60
b3-06
Speed
Estimation
Current
Level 1
- 0.5 0.5 0.5 0.5 0.5 0.7 0.7 0.7 0.7
b3-08
Speed
Estimation
ACR P Gain
- 0.50 0.50 0.50 0.50 0.50 0.80 0.80 0.80 0.80
b3-11
Spd Est
Method
Switch-over
Level
% 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0
b3-12
Speed Search
Current
Deadband
- 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
b3-26
Direction
Determina
tion Level
- 1000 1000 1000 1000 1000 1000 1000 1000 1000
b8-04
Energy
Saving
Coefficient
Value
- 103.58 92.54 76.32 71.56 67.2 46.2 38.91 36.23 30.13
C6-02
Carrier
Frequency
Selection
- 2 2 2 2 2 2 2 2 1
E2-01
Motor Rated
Current
(FLA)
A 52.0 65.0 77.0 96.0 124.0 156.0 180.0 240.0 302.0
E2-02
Motor Rated
Slip
Hz 1.70 1.80 1.33 1.60 1.46 1.39 1.40 1.40 1.35
E2-03
Motor No-
Load Current
A 9.2 10.9 19.1 22 24 36 40 49.00 70
E2-05
Motor Line-
to-Line
Resistance
Ω 0.316 0.269 0.155 0.122 0.088 0.092 0.056 0.05 0.029
E2-06
Motor
Leakage
Inductance
% 23.5 20.7 18.8 19.9 20.0 20.0 20.0 20.00 20.0
E2-10
Motor Iron
Loss
W 586 750 925 1125 1260 1600 1760 2150 2850