EasyManua.ls Logo

YASKAWA OYMC V1000

YASKAWA OYMC V1000
408 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A.2 Parameter Table
YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual 319
Parameter List
A
E3-04
Motor 2 Max
Output
Frequency
These parameters set the V/f pattern for motor
2.
To set linear V/f characteristics, set the same
values for E3-07 and E3-09. In this case, the
setting for E3-08 will be disregarded. Ensure
that the four frequencies are set according to
these rules or OPE10 fault will occur:
E3-04 E3-06 > E3-07 > E3-09
40.0 to
400.0
50 Hz A A 31A 120
E3-05
<24>
Motor 2 Max
Vo l t a g e
0.0 to
255.0
200.0
V
AA 31B 120
E3-06
Motor 2 Base
Frequency
0.0 to E3-
04
50 Hz A A 31C 120
E3-07
Motor 2 Mid
Output Freq.
0.0 to E3-
04
2.5 Hz
<53>
AA 31D 120
E3-08
<24>
Motor 2 Mid
Output Freq.
Vo l t a g e
0.0 to
255.0
16.0 V
<12>
<53>
AA 31E 120
E3-09
Motor 2 Min.
Output Freq.
0.0 to E3-
04
1.3 Hz
<53>
AA 31F 120
E3-10
<24>
Motor 2 Min.
Output Freq.
Vo l t a g e
0.0 to
255.0
12.0 V
<12>
<53>
AA 320 120
E3-11
<26>
Motor 2 Mid
Output
Frequency 2
0.0 to E3-
04
0.0 Hz A A 345 120
E3-12
<24>
<52>
Motor 2 Mid
Output
Frequency
Voltage 2
0.0 to
255.0
<24>
0.0 Vac A A 346 120
E3-13
<24>
Motor 2 Base
Vo l t a g e
0.0 to
255.0
<24>
0.0 Vac A S 347 120
E4: Motor 2 Parameters
Use E4 parameters to control a second motor operating on the same drive.
E4-01
Motor 2 Rated
Current
Sets the motor 2 nameplate full load current in
amperes (A). This value is automatically set
during Auto-Tuning.
10 to
200% of
drive
rated
current
<57> AA 321 121
E4-02
Motor 2 Rated
Slip
Sets the motor 2 rated slip in Hz.
Automatically set during Auto-Tuning.
0.00 to
20.00
<57> AA 322 121
E4-03
Motor 2 Rated
No-Load
Current
Sets the magnetizing current of motor 2 in
Ampere. Automatically set during Rotational
Auto-Tuning.
0 to less
than
E4-01
<27>
<57> AA 323 121
No. Name Description Range Def.
Control
Mode
Addr.
Hex
Pg.
V/f
OL
V
PM
V
ACrms Out (V)
Frequency (Hz)
E3-09 E3-07 E3-06 E3-11 E3-04
E3-05
E3-12
E3-13
E3-08
E3-10

Table of Contents

Related product manuals