No. Parameter Name Default Setting
L8-07 Output Phase Loss Protection Selection 1: Triggered when a single phase is lost
L8-38 Carrier Frequency Reduction 1: Enabled below 6 Hz
L8-41 High Current Alarm Selection 1: Enabled (alarm output)
<1> Disable L8-05 for single-phase models.
Table 4.16 Preset 7: User Parameters (A2-01 to A2-16):
No. Parameter Name No. Parameter Name
b1-01 Frequency Reference Selection 1 d1-03 Frequency Reference 3
C1-01 Acceleration Time 1 E2-01 Motor Rated Current
C1-02 Deceleration Time 1 H1-05
Multi-Function Digital Input Terminal
S5 Function
C6-02 Carrier Frequency Selection H1-06
Multi-Function Digital Input Terminal
S6 Function
d1-01 Frequency Reference 1 H2-01
Terminals MA, MB, and MC Function
Selection
d1-02 Frequency Reference 2 L1-01 Motor Overload Protection Selection
u
Setting 8: Conveyor Application 2
This setting is available in drive software versions PRG: 1020 and later.
Table 4.17 Conveyor 2: Parameters and Settings
No. Parameter Name Default Setting
A1-02 Control Method Selection 0: V/f Control
C1-01 Acceleration Time 1 3.0 s
C1-02 Deceleration Time 1 3.0 s
C6-01 Drive Duty Selection 0: Heavy Duty
L3-04
Stall Prevention Selection during
Deceleration
0: Disabled
n3-13 Overexcitation Deceleration Gain 1.4
n3-21 High-Slip Suppression Current Level 150%
4.5 Application Selection
104
YASKAWA ELECTRIC TOEP C710606 47A YASKAWA AC Drive – V1000 Quick Start Guide