Types of Auto-Tuning ........................................................ 113
Before Auto-Tuning the Drive .............................................. 113
Auto-Tuning Interruption and Fault Codes.............................. 115
Performing Auto-Tuning ..................................................... 115
Auto-Tuning Example ........................................................ 117
Input Data for Auto-Tuning.................................................. 119
4.8 No-Load Operation Test Run ..........................................123
No-Load Operation Test Run............................................... 123
4.9 Test Run with Load Connected.......................................125
Test Run with the Load Connected....................................... 125
4.10 Test Run Checklist .........................................................126
5. TROUBLESHOOTING ...............................................129
5.1 Drive Alarms, Faults, and Errors.....................................130
Types of Alarms, Faults, and Errors...................................... 130
5.2 Fault Detection ...............................................................131
Fault Displays, Causes, and Possible Solutions ...................... 131
5.3 Alarm Detection..............................................................146
Alarm Codes, Causes, and Possible Solutions........................ 146
5.4 Operator Programming Errors........................................149
oPE Codes, Causes, and Possible Solutions .......................... 149
5.5 Auto-Tuning Fault Detection...........................................150
Auto-Tuning Codes, Causes, and Possible Solutions ............... 150
5.6 Diagnosing and Resetting Faults....................................153
Fault Reset Methods ......................................................... 153
A. SPECIFICATIONS......................................................155
A.1 Heavy Duty and Normal Duty Ratings.............................156
A.2 Single/Three-Phase 200 V Class Drives ..........................157
A.3 Three-Phase 400 V Class Drives.....................................160
A.4 Drive Specifications........................................................162
B. PARAMETER LIST ....................................................167
Table of Contents
6
YASKAWA ELECTRIC TOEP C710606 47A YASKAWA AC Drive – V1000 Quick Start Guide

Table of Contents

Other manuals for YASKAWA V1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA V1000 and is the answer not in the manual?

YASKAWA V1000 Specifications

General IconGeneral
Input Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Frequency0-400 Hz
Control MethodV/f control
Overload Capacity150% for 60 seconds
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit, Ground Fault
Communication OptionsModbus RTU
Ambient Temperature-10 to +50°C (14 to 122°F)
Storage Temperature-20°C to +65°C (-4°F to 149°F)
Humidity95% (non-condensing)
Cooling MethodForced Air Cooling
EnclosureIP20