2 Vertical Axis
This section explains how to configure the signal input settings and the amplitude-direction display settings. The
items that can be set vary depending on the installed modules.
Input Settings
CH1 to CH16
The channel menu that corresponds to the key you pressed appears. You can set the various vertical axis
settings for each channel.
ALL CH
You can configure the settings of all channels while viewing the settings in a list. You can also copy the various
vertical axis settings of one channel to another channel. There are some items that cannot be configured from
the ALL CH menu.
DL850E/DL850EV Measurement Items
When the DL850E/DL850EV is equipped with the modules listed below, it can measure voltage, temperature,
strain, acceleration, frequency, logic, CAN bus signals, LIN bus signals, and so on.
Voltage measurement
701250 (HS10M12), 701251 (HS1M16), 701255 (NONISO_10M12), 701267 (HV (with RMS)),
720210 (HS100M12), 701261 (UNIVERSAL), 701262 (UNIVERSAL (AAF)), 701265 (TEMP/HPV),
701275 (ACCL/VOLT)
Y
ou can install up to four 720210 modules, and these modules must be installed in the top slots.
Voltage measurement (for the 16-CH Voltage Input Module
)
720220 (16CH VOLT)
Temperature measurement
701261 (UNIVERSAL), 701262 (UNIVERSAL (AAF)), 701265 (TEMP/HPV)
Temperature measurement (for the 16-CH Temperature/Voltage Input Module
)
720221 (16CH TEMP/VOLT)
Strain measurement
701270 (STRAIN_NDIS), 701271 (STRAIN_DSUB)
Acceleration measuremen
t
701275 (ACCL/VOLT)
Frequency measurement
701280 (FREQ)
Logic measurement
720230 (LOGIC)
CAN Bus Signal Monitorin
g
720240 (CAN MONITOR), 720241 (CAN & LIN)
These modules can be used only with the DL850EV. You can install up to a total of two 720240 or 720241
modules in slots 7 and 8.
LIN Bus Signal Monitorin
g
720241 (CAN & LIN)
This module can be used only with the DL850EV. You can install up to two 720241 modules in slots 7 and 8.
You can use auto setup to automatically configure the appropriate settings (such as vertical axis, horizontal
axis, and trigger settings) for the input signal. This feature is useful when you are not sure what type of signal
will be applied to the DL850E/DL850EV. The auto setup feature will not work properly on some input signals.
Also, there are some modules with which the auto setup feature cannot be used.
Digital Filter and Real Time Math (Optional)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA ScopeCorder DL850E and is the answer not in the manual?

YOKOGAWA ScopeCorder DL850E Specifications

General IconGeneral
BrandYOKOGAWA
ModelScopeCorder DL850E
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals