120
Enable system logcat - Enables logging for this logcat buffer.
System log interval (sec) - Sets the interval, in seconds, on which to flush the log buffer to the file.
System log filename - Specifies the base log filename for this logcat buffer. The current file count is
appended to this name.
System log file count - Specifies the number of log files to keep and rotate through. Each log file is
subject to the max log size option.
System log file size (MB) - Specifies the maximum size, in kilobytes, of an individual log file.
System log filter - Custom logcat filter to run on the system buffer.
Enable crash logcat- Enables logging for this crash logcat buffer.
Crash log interval (sec) - Sets the interval, in seconds, on which to flush the log buffer to the file.
Crash log filename - Specifies the base log filename for this logcat buffer. The current file count is
appended to this name.
Crash log file count - Specifies the number of log files to keep and rotate through. Each log file is
subject to the max log size option.
Crash log file size (MB) - Specifies the maximum size, in megabytes, of an individual log file.
Crash log filter - Custom logcat filter to run on the crash buffer.
Enable combined logcat - Enables logging for this logcat buffer.
Enable main buffer - Enable or disable the addition of the main buffer into the combined logcat file.
Enable event buffer - Enable or disable the addition of the event buffer into the combined logcat file.
Enable radio buffer - Enable or disable the addition of the radio buffer into the combined logcat file.
Enable system buffer - Enable or disable the addition of the system buffer into the combined logcat file.
Enable crash buffer - Enable or disable the addition of the crash buffer into the combined logcat file.
Combine log interval (sec) - Sets the interval, in seconds, on which to flush the log buffer to the file.
Combined log filename - Specifies the base log filename for this logcat buffer. The current file count is
appended to this name.
Combined log file count - Specifies the number of log files to keep and rotate through. Each log file is
subject to the max log size option.
Combined log file size (MB) - Specifies the maximum size, in megabytes, of an individual log file.
Combined log filter - Custom logcat filter to run on the combined buffer.
LTS Module
The LTS (Long Term Storage) Module captures data over a long duration of time without losing any data.
Whenever a file is done being written, LTS saves it as a GZ file in an organized path for later use.
Enable Module - Enables logging for this module.
Storage Directory - Specifies the high level log path for storage of all logcat logs. This setting applies
globally to all logcat buffers.
Qxdm Module
The Ramoops Module captures Qualcomm Modem Logs from the device.
Enable Module - Enables logging for this module.
Log path - Specifies the storage path for Qxdm files.
Qxdm Log Size - Specifies the maximum size, in kilobytes, of an individual log file.
Qxdm test sets to keep - Specifies the number of test sets to keep. One test set is a start and stop.