EasyManuals Logo
Home>Zebra>PDA>TC20

Zebra TC20 User Manual

Zebra TC20
171 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
DataWedge
67
Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the
data. Enables or disables this option. A check in the checkbox indicates that the option is enabled (default -
disabled).
UPCE1
Convert UPCE1 To UPCA - Enable this to convert UPCE1 decoded data to UPC-A format before
transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming
selections. Disable this to transmit UPCE1 decoded data as UPCE1 data, without conversion (default -
disabled).
Preamble - Preamble characters are part of the UPC symbol consisting of Country Code and System
Character. Select the appropriate option to match the host system.
There are three options for transmitting a UPCE1 preamble:
Preamble None - Transmit no preamble (default).
Preamble Sys Char - Transmit System Character only.
Preamble Country and Sys Char - Transmit System Character and Country Code (“0” for USA).
Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the
data. Enables or disables this option. A check in the checkbox indicates that the option is enabled (default -
disabled).
US Planet
Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the
data. Enables or disables this option. A check in the checkbox indicates that the option is enabled (default -
disabled).
Decode Lengths
The allowable decode lengths are specified by options Length1 and Length2 as follows:
Variable length: Decode symbols containing any number of characters.
Set both Length1 and Length2 to 0.
Range: Decode a symbol with a specific length range (from
a
to
b
, including
a
and
b
).
Set Length1 to
a
and set Length2 to
b
.
Two Discrete Lengths: Decode only symbols containing either of two selected lengths.
Set both Length1 or Length2 to the specific lengths. Length1 must be greater than Length2.
One Discrete Length: Decode only symbols containing a specific length.
Set both Length1 and Length2 to the specific length.
UPC EAN Params
Allows the configuration of the parameters that apply to more than one UPC or EAN decoder.
NOTE: Not all parameter options are available with all scanners. See the DataWedge app on each device for the available
scanners and parameter options.
Convert DataBar To UPC EAN - If this is set it converts DataBar barcodes to UPC/EAN format. For this
setting to work UPC/EAN symbologies must be enabled. A check in the checkbox indicates that the option
is enabled. (default - disabled).
UPC Reduced Quiet Zone - Enables decoding of margin-less UPC barcodes. (default - disabled)
Bookland - Enable Bookland decoding. A check in the checkbox indicates that the option is enabled.
(default - disabled).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra TC20 and is the answer not in the manual?

Zebra TC20 Specifications

General IconGeneral
BrandZebra
ModelTC20
CategoryPDA
LanguageEnglish

Related product manuals