ZXR105900/5200SeriesUserManual(BasicCongurationVolume)
ViewingModuleThresholdInformation
CommandFunction
ZXR10#showoptical-informdetail[temperature
voltagecurrentrx-powertx-power][interface
<interface-name>]
Thisviewsdetailedthreshold
informationofinterfaceoptical
moduleincludestemperature,
voltage,current,sendingand
receivingpower .Thissupports
singleinterfaceviewandsingle
boardview.
Commandparameterdescription+:
Parameter
Description
interface<interface-name>interfacename
temperature
Opticalmoduletemperature
voltageOpticalmodulevoltage
current
Opticalmodulecurrent
rx-power
receivingpowerofopticalmodule
tx-power
sendingpowerofopticalmodule
Onlysupportphysicalinterface.
ExampleThisviewsthresholdinformationofinterfaceopticalmodule.
ZXR10#showoptical-informdetailtemperature
HighAlarmHighWarnLowWarnLowAlarm
TemperatureThresholdThresholdThresholdThreshold
Port(Celsius)(Celsius)(Celsius)(Celsius)(Celsius)
-----------------------------------------------------------
gei_1/148.1100.0100.00.00.0
gei_1/234.9100.0100.00.00.0
ZXR10#Showoptical-informdetailVoltage
HighAlarmHighWarnLowWarnLowAlarm
VoltageThresholdThresholdThresholdThreshold
Port(Volts)(Volts)(Volts)(Volts)(Volts)
------------------------------------------------------
gei_1/13.306.506.503.503.50
gei_1/23.306.506.503.503.50
Thethresholdisrelatedtohardwareopticalmodule.Ifopticalmod-
uleandmanufactureraredifferenttheviewedinformationwillbe
different.
44CondentialandProprietaryInformationofZTECORPORATION