Chapter 9 Maintenance
HES-309M Series User’s Guide
122
9.6 SNMP
Use this screen to allow remote access to the WiMAX Device from a network
connection over SNMP.
Click Maintenance > Remote MGMT > SNMP to open this screen as shown
next.
Figure 55 SNMP Screen
This screen contains the following fields:
Table 45 SNMP
LABEL DESCRIPTION
Enable Select this to enable remote management using this service.
Location Enter the location of the SNMP server (for example, “Engineering Dept.,
Floor 6, Building A, New York City”).
Contact Enter contact information for the administrator managing the SNMP
server (for example, “Bill Smith, IT Dept., (555) 555-5454”).
Read
Community
Enter the password for the incoming Get and GetNext requests from the
management station. The default is public and allows all requests.
Write
Community
Enter the password for incoming Set requests from the management
station. The default is public and allows all requests.
Trap Server Enter the IP address of the station to send your SNMP traps to.
Trap
Community
Enter the trap community, which is the password sent with each trap to
the SNMP manager. The default is public and allows all requests.