Chapter 55 Static MAC Forwarding
XGS2220 Series User’s Guide
365
55.2.1 Add/Edit Static MAC Forwarding Rules
Click Add/Edit, or select an entry and click Add/Edit in the SWITCHING > Static MAC Forwarding screen
to display this screen.
Figure 265 SWITCHING > Static MAC Forwarding > Add/Edit
The following table describes the labels in this screen.
MAC Address This field displays the MAC address that will be forwarded and the VLAN identification number to
which the MAC address belongs.
VID This field displays the ID number of the VLAN group.
Port This field displays the port where the MAC address shown in the next field will be forwarded.
Select an entry’s check box to select a specific entry. Otherwise, select the check box in the table
heading row to select all entries.
Add/Edit Click Add/Edit to add a new rule or edit a selected one.
Delete Click Delete to remove the selected rules.
Table 194 SWITCHING > Static MAC Forwarding (continued)
LABEL DESCRIPTION
Table 195 SWITCHING > Static MAC Forwarding > Add/Edit
LABEL DESCRIPTION
Active Enable the switch button to activate your rule. You may temporarily deactivate a rule without
deleting it by disabling the switch.
Name Enter a descriptive name for identification purposes for this static MAC address forwarding rule.
You can enter up to 32 printable ASCII characters except [ ? ], [ | ], [ ' ], [ " ] or [ , ].
MAC Address Enter the MAC address in valid MAC address format, that is, six hexadecimal character pairs.
Note: Static MAC addresses do NOT age out.
VID Enter the VLAN identification number.
Port Enter the port where the MAC address entered in the previous field will be automatically
forwarded.
Apply Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to save
your changes to the non-volatile memory when you are done configuring.
Clear Click Clear to clear the fields to the factory defaults.
Cancel Click Cancel to not save the configuration you make and return to the last screen.