45
K-Test Summary
If you press the [Enter] key in the previous screen, 
the 965DSP will display the following summary of 
up to five K-Test results:
The 965DSP displays the Resistance to Faults 
(RTF), Resistance Strap to Faults (RSTF), and 
the Resistance to Strap (RTS) for up to five 
measurements.  
The 965DSP also displays the average value of the 
five measurements. In general, the average value 
of many readings is more accurate than a single 
reading. 
Use the [Enter] key to display the last K-Test result. 
Use the [Tab] key to select distance instead of 
resistance. Use the [Setup] key to change the wire 
gauge or the temperature used for the conversion 
from resistance to distance.