K-Test Error: Flip red and green
The 965DSP will first make a measurement to
verify that the heavier fault is connected to red and
the lighter fault is connected to green.
If the size of faults is reversed, you will see the
following screen: K-Test Error
This screen indicates that the connections to the red
and green leads are reversed and the leads should be
swapped or “flipped. Leave the black lead connected
to the reference wire.
Press the [Enter] key to retest the connection
after swapping the leads, or press the [Tab] key to
continue without retesting the connection.